Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Prosthet Dent ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580583

RESUMO

STATEMENT OF PROBLEM: The type of veneer preparation is often chosen according to the patient's tooth structure and occlusion. Taking biomechanics into account in this decision-making process provides the clinician with more technical information on how to improve the clinical longevity of restorations. However, biomechanical analyses of veneer preparation designs are sparse. PURPOSE: The purpose of this 3-dimensional (3D) finite element analysis with microcomputed tomography (µCT) data obtained from realistic models was to assess the influence of different preparations for ceramic and composite resin veneers on restoration and resin layer stress distribution. MATERIAL AND METHODS: Four replicas of a central incisor were printed and prepared for laminate veneers with 4 different incisal edge designs: shoulder (SH), palatal chamfer (PC), palatal chamfer and oblique fracture involving the distal angle (OF-PC), and palatal chamfer involving horizontal incisal fracture (IF-PC). After fabrication and cementation of the veneers, the restored replicas were assessed with µCT, and 3D finite element models were built. A 100-N load was applied on the palatal surface at 60 and 125 degrees relative to the longitudinal axis. Maximum principal stress and stress distribution on the veneers, cement layer, and tooth structure were calculated and analyzed. RESULTS: The SH preparation exhibited better stress distribution than the PC preparation, and the cement layer and the veneer were subjected to lower stress. The IF-PC preparation had better stress distribution than the OF-PC. The shoulder and IF-PC showed higher stress on laminate veneers, but lower stress on the cement layer. Ceramic veneers exhibited lower stress than composite resin veneers. CONCLUSIONS: The different incisal preparations for laminate veneers influenced stress distribution on restorations and on the resin cement layer. The shoulder type preparation showed better stress distribution and the composite resin veneers showed unfavorable results compared with the ceramic veneers.

2.
Braz Oral Res ; 34: e105, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32876118

RESUMO

The aim of this research was to evaluate the influence of MDP (10-methacryloyloxydecyl dihydrogen phosphate) concentration and application mode of experimental adhesives on microshear bond strength (µSBS) to dentin after storage in distilled water at 37°C for 24h and 6 months. Five experimental adhesives were prepared with: CQ, DABE, BHT, ethanol, HEMA, TEGDMA, Bis-EMA, UDMA, and Bis-GMA. Concentrations of 0 wt%, 3 wt%, 9 wt%, 12 wt% or 15 wt% of MDP were added to their composition. The adhesives were applied to flat dentin surfaces in etch-and-rinse or self-etching modes. Cylindrical molds filled with light-cured composite resin were placed above the dentin. The specimens were stored in distilled water at 37oC for 24h or 6 months and submitted to µSBS testing. The adhesives were also submitted to pH analysis. The data were analyzed by one-way ANOVA, three-way ANOVA and Tukey's test (α = 5%). All the adhesives used in the etch-and-rinse mode showed significantly higher bond strength than the adhesives applied in the self-etching approach. The 9 wt% adhesive showed the highest bond strength values, and 3 wt% was most stable after storage. A strong negative correlation between MDP concentration and pH was observed. It was concluded that the formulations with low concentrations of MDP (up to 9 wt%) showed better results for bond strength and bond strength degradation over time.


Assuntos
Colagem Dentária , Adesividade , Resinas Compostas , Cimentos Dentários , Dentina , Adesivos Dentinários , Teste de Materiais , Cimentos de Resina , Resistência à Tração
3.
Braz Oral Res ; 33(suppl 1): e068, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31576952

RESUMO

The objective of this systematic review was to compare the conical internal connection (IC) with the external hexagonal connection (EH) on the occurrence of marginal bone loss (ΔMBL). Different databases were used to carry out the selection of the elected studies. The studies were judged according to the risk of bias as "high", "low" and "unclear" risk. For the meta-analysis we included only studies that could extract the data of ΔMBL, survival rate (SR) and probing depth (PD). No statistically significant differences were found for ΔMBL data at one, three- and five-year survival rates between implant connections (p <0.05), however statistically significant differences were found for PD between EH and IC implants (1-year follow-up) -0.53 [95%CI -0.82 to -0.24, p = 0.0004]. This present systematic review demonstrated that there are no significant differences between IC and EH implants for both ΔMBL and SR at 1, 3 e 5 years after functional loading, although better PD values were observed for implants pertaining to the IC connections. Considering the high heterogeneity, more well-delineated, randomized clinical trials should be conducted.


Assuntos
Perda do Osso Alveolar/etiologia , Dente Suporte/efeitos adversos , Projeto do Implante Dentário-Pivô/efeitos adversos , Implantes Dentários/efeitos adversos , Humanos , Valores de Referência , Medição de Risco , Fatores de Risco , Fatores de Tempo
4.
PLoS One ; 14(7): e0219183, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31260461

RESUMO

The influence of curing mode and shade of resin cements on the color stability of minimum-thickness ceramic veneers after a three-year storage time in distilled water was evaluated in this study. Ninety-six 0.5-mm-thick feldspathic ceramic veneers (Mark II) were luted onto resin composite substrates (Filtek Z350 XT, shade A2E) with two light-cured (NX3 Light-cure and AllCem Veneer) and dual-cured resin cements (NX3 dual-cure and AllCem) in various shades. The specimens were stored in distilled water at 37°C. Color measurements were performed with a spectrophotometer at the following times: 1h and 24h; 7, 30, and 180 days; and 1, 2, and 3 years. Data for color difference (ΔEab) light-cured and dual-cured resin cements were analyzed by two-way ANOVA with repeated measures and Tukey's test (α = 0.05). For the light-cured cements, the ΔEab values were as follows: NX3-Yellow (2.37±1.35) = ACV-A1 (2.40±1.21) = ACV-Trans (2.52±1.46) = ACV-E-Bleach M (2.56±1.42) = NX3-White (2.69±1.49) = NX3-Clear (2.98±1.68). The lowest ΔE values were found for 1 h (0.61±0.36)a, followed by 24 h (1.15±0.55)b and 30 days (2.48±1.11)c. One year, 180 days, and 2 and 3 years presented higher ΔEab values (3.34±0.94, 3.52±1.04, 3.52±0.95 and 3.55±1.14, respectively)d. For the dual-cured cements, the ΔEab values varied as follows: NX3-Clear (2.32±1.24)a = NX3-Yellow (2.37±1.32)a = NX3-White (2.76±1.43)a < AC-Trans (3.77±1.91)b = AC-A3 (4.13±2.11)b < AC-A1 (5.38±2.92)c. Considering time, the lowest ΔEab values were found for 1 h (0.48±0.25)a, followed by 24 h (2.13 ±0.83)b, 30 days (3.54±1.31)c, and 180 days (3,70±1.73)c. The follow-up times of 1 (4.43±2.15)d, 2 (5.02±1.74)e, and 3 years (4.90±2.12)e presented higher ΔEab values. This study demonstrated that light-cured resin cements were less susceptible to color change than dual-cured cements. After 2 years of follow-up, all cements presented ΔEab values above the acceptability threshold.


Assuntos
Cerâmica/química , Facetas Dentárias , Cura Luminosa de Adesivos Dentários , Cimentos de Resina/química , Autocura de Resinas Dentárias , Cor , Estética , Teste de Materiais , Espectrofotometria , Propriedades de Superfície , Fatores de Tempo
5.
Braz. oral res. (Online) ; 33(supl.1): e068, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1039311

RESUMO

Abstract The objective of this systematic review was to compare the conical internal connection (IC) with the external hexagonal connection (EH) on the occurrence of marginal bone loss (ΔMBL). Different databases were used to carry out the selection of the elected studies. The studies were judged according to the risk of bias as "high", "low" and "unclear" risk. For the meta-analysis we included only studies that could extract the data of ΔMBL, survival rate (SR) and probing depth (PD). No statistically significant differences were found for ΔMBL data at one, three- and five-year survival rates between implant connections (p <0.05), however statistically significant differences were found for PD between EH and IC implants (1-year follow-up) -0.53 [95%CI -0.82 to -0.24, p = 0.0004]. This present systematic review demonstrated that there are no significant differences between IC and EH implants for both ΔMBL and SR at 1, 3 e 5 years after functional loading, although better PD values were observed for implants pertaining to the IC connections. Considering the high heterogeneity, more well-delineated, randomized clinical trials should be conducted.


Assuntos
Humanos , Implantes Dentários/efeitos adversos , Perda do Osso Alveolar/etiologia , Dente Suporte/efeitos adversos , Projeto do Implante Dentário-Pivô/efeitos adversos , Valores de Referência , Fatores de Tempo , Fatores de Risco , Medição de Risco
6.
Braz Oral Res ; 30(1): e113, 2016 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-27737366

RESUMO

The objective of this study was to evaluate the marginal and internal fit of zirconia copings obtained with different digital scanning methods. A human mandibular first molar was set in a typodont with its adjacent and antagonist teeth and prepared for an all-ceramic crown. Digital impressions were made using an intraoral scanner (3Shape). Polyvinyl siloxane impressions and Type IV gypsum models were also obtained and scanned with a benchtop laboratory scanner (3Shape D700). Ten zirconia copings were fabricated for each group using CAD-CAM technology. The marginal and internal fit of the zirconia copings was assessed by the silicone replica technique. Four sections of each replica were obtained, and each section was evaluated at four points: marginal gap (MG), axial wall (AW), axio-occlusal edge (AO) and centro-occlusal wall (CO), using an image analyzing software. The data were submitted to one-way ANOVA and Tukey's test (α = 0.05). They showed statistically significant differences for MG, AO and CO. Regarding MG, intraoral scanning showed lower gap values, whereas gypsum model scanning showed higher gap values. Regarding AO and CO, intraoral digital scanning showed lower gap values. Polyvinyl siloxane impression scanning and gypsum model scanning showed higher gap values and were statistically similar. It can be concluded that intraoral digital scanning provided a lower mean gap value, in comparison with conventional impressions and gypsum casts scanned with a standard benchtop laboratory scanner.


Assuntos
Técnica de Moldagem Odontológica/instrumentação , Adaptação Marginal Dentária , Zircônio/química , Análise de Variância , Sulfato de Cálcio/química , Desenho Assistido por Computador , Técnica de Fundição Odontológica , Materiais para Moldagem Odontológica/química , Planejamento de Prótese Dentária , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Teste de Materiais , Polivinil/química , Valores de Referência , Reprodutibilidade dos Testes , Siloxanas/química
7.
Braz. oral res. (Online) ; 30(1): e113, 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-951952

RESUMO

Abstract The objective of this study was to evaluate the marginal and internal fit of zirconia copings obtained with different digital scanning methods. A human mandibular first molar was set in a typodont with its adjacent and antagonist teeth and prepared for an all-ceramic crown. Digital impressions were made using an intraoral scanner (3Shape). Polyvinyl siloxane impressions and Type IV gypsum models were also obtained and scanned with a benchtop laboratory scanner (3Shape D700). Ten zirconia copings were fabricated for each group using CAD-CAM technology. The marginal and internal fit of the zirconia copings was assessed by the silicone replica technique. Four sections of each replica were obtained, and each section was evaluated at four points: marginal gap (MG), axial wall (AW), axio-occlusal edge (AO) and centro-occlusal wall (CO), using an image analyzing software. The data were submitted to one-way ANOVA and Tukey's test (α = 0.05). They showed statistically significant differences for MG, AO and CO. Regarding MG, intraoral scanning showed lower gap values, whereas gypsum model scanning showed higher gap values. Regarding AO and CO, intraoral digital scanning showed lower gap values. Polyvinyl siloxane impression scanning and gypsum model scanning showed higher gap values and were statistically similar. It can be concluded that intraoral digital scanning provided a lower mean gap value, in comparison with conventional impressions and gypsum casts scanned with a standard benchtop laboratory scanner.


Assuntos
Humanos , Zircônio/química , Técnica de Moldagem Odontológica/instrumentação , Adaptação Marginal Dentária , Polivinil/química , Valores de Referência , Siloxanas/química , Processamento de Imagem Assistida por Computador/instrumentação , Teste de Materiais , Sulfato de Cálcio/química , Reprodutibilidade dos Testes , Análise de Variância , Técnica de Fundição Odontológica , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Materiais para Moldagem Odontológica/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...